Multi-Function Input Variables - Omron 3G3MX2 Series User Manual

Drive programming
Hide thumbs Also See for 3G3MX2 Series:
Table of Contents

Advertisement

9 LX inverter
Precautions for Correct Use
• When the Drive Programming program is stopped, the data of the analog output terminal
variables before the program stop is retained. When the program execution is started again,
the process begins with the retained data. However, the outputs with the Drive Programming
not set are controlled as the inverter's analog outputs independently of the program.
• The multi-function digital output (PWM output) FM terminal provides PWM signal outputs.
The terminal outputs the value of 0.00 to 100.00% (variable) as the pulse width (duty ratio
t/T) in a 6.4 ms cycle.
PWM output
9-4-2

Multi-function Input Variables

Function variable
UP
DWN
SPD1
SPD2
SPD3
SET
FRS
EXT
SFT
RS
OLR
TL
TRQ1
TRQ2
PCLR
KHC
X(00) to X(11)
EMP
INSP
RL
COK
BOK
FP1 to FP6
PAL
TCL
LVS
9 - 10
t
T
Cycle T: Constant (6.4 ms)
Duty ratio t/T: Variable
Description
Upward RUN
Downward RUN
Multi-speed 1 setting
Multi-speed 2 setting
Multi-speed 3 setting
2nd Control
Free-run stop
External trip
Soft lock
Reset
Change OL-level
Torque limit enable
Change Torque limit 1
Change Torque limit 2
Clear the current position
Kwh clear
Drive Programming MI1 to MI12
Em-Power operation
Inspection
Releveling
Contactor check signal
Brake check signal
Floor position 1 to 6
Auto learning data latch trigger
Torque bias latch trigger
Levelling signal
R/W
Reference
C001 to C007  00
R/W
C001 to C007  01
R/W
C001 to C007  02
R/W
C001 to C007  03
R/W
C001 to C007  04
R/W
C001 to C007  08
R/W
C001 to C007  11
R/W
C001 to C007  12
R/W
C001 to C007  15
R/W
C001 to C007  18
R/W
C001 to C007  32
R/W
C001 to C007  33
R/W
C001 to C007  34
R/W
C001 to C007  35
R/W
C001 to C007  40
R/W
C001 to C007  46
R/W
C001 to C007  49 to 60
R/W
C001 to C007  61
R/W
C001 to C007  62
R/W
C001 to C007  63
R/W
C001 to C007  64
R/W
C001 to C007  65
R/W
C001 to C007  66 to 71
R/W
C001 to C007  72
R/W
C001 to C007  73
R/W
C001 to C007  74
R/W
Drive Programming User's Manual (I580-E2)