Assembling and Connecting the V680S-A42@M Cable and Connector
Assembly Method
Follow the table below, assemble the connector.
Prepare the shielded-connectors according to the application.
Wire color
Brown
(Drain wire)
Purple
Orange
Green/White(stripe)
Orange/White(stripe)
Blue
Green
Example Connection
V680S-A42
M
V680S-A42
M
Wire color
Name
Orange/White
TD+
Ethernet send data +
Orange
TD-
Ethernet send data -
Green/White
RD+
Ethernet receive data +
Green
RD-
Ethernet receive data -
Following the instructions of the manufacturer of the connector, ground connecting the FG with the connector side.
Connecting the Host Device
Connect the connector on the V680S-A42@M Cable to an Ethernet port on the host device.
The Reader/Writer supports for Auto-MDIX, can communicate by both straight and cross ethernet lines.
Use a device supporting STP cables for the host device (such as an Ethernet switch or PLC) which is connected the
specified Cables (V680S-A42 @M). Ground the host device to a ground resistance of 100 Ω or less.
Name
Function
24P
+24V
FG
Frame ground
CONT
Control signal
TD-
Ethernet send data -
RD+
Ethernet receive data +
TD+
Ethernet send data +
24N
0V
RD-
Ethernet receive data -
Function
Installation and Connections
Applicable wire
AWG20
---
AWG24
AWG24
AWG24
AWG24
AWG20
AWG24
M12 Connector
Power supply lines, Control signal line
M12 Connector
Name
Function
TXP
Transmitted data (+)
TXN
Transmitted data (-)
RXP
Received data (+)
RXN
Received (-)
Section 4
RFID System
85
User's Manual
(Modbus TCP)