Omron V680S-HMD63-ETN User Manual page 188

V680s series
Hide thumbs Also See for V680S-HMD63-ETN:
Table of Contents

Advertisement

Section 7
Host Communications Specifications
 GET Reader/Writer OPERATING STATUS
This query reads the operating status from the Reader/Writer.
 Query Format
Byte 0
Byte 1
Transaction
identifier
X
Parameter
Register address
Word count
 Response Format
Normal Response
Byte 0
Byte 1
Transaction
identifier
X
X
Byte count
Reader/Writer
operating status
Error Response
Byte 0
Byte 1
Transaction
identifier
X
Parameter
Exception code
 Execution Example
Reading Status When the Reader/Writer Is in Run Mode and Idling
TX: 000000000006FF03C3000002
RX: 000000000007FF030400010001
RFID System
186
User's Manual
(Modbus TCP)
Byte 2
Byte 3
Byte 4
Protocol identifier
Field length
X
0000 hex
0006 hex
The register address (C300 hex) that specifies the Reader/Writer operating status.
The number of words in the Reader/Writer operating status to read (0002 hex)
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Protocol
Unit
Field length
identifier
identifier
0000 hex
0007 hex
FF hex
Parameter
The number of bytes in the Reader/Writer operating status that was read (04 hex)
Mode
Contains the mode of the Reader/Writer that was read in 4-digits hexadecimal.
0000 hex: Safe Mode
0001 hex: Run Mode
0002 hex: Slave Mode
Status
Contains the status of the Reader/Writer that was read in 4-digits hexadecimal.
information
0000 hex: Initializing
0001 hex: Idling
0002 hex: RF Tag communications in progress
0003 hex: Downloading
0004 hex: Error
0005 hex: Shutdown in progress
Byte 2
Byte 3
Byte 4
Protocol identifier
Field length
X
0000 hex
For details, refer to Exception Code Table in this section.
p.157
Byte 5
Byte 6
Byte 7
Unit
Function
identifier
code
FF hex
03 hex
Description
Byte 7
Byte 8
Function code
Byte count
03 hex
04 hex
Description
Byte 5
Byte 6
Byte 7
Unit
Function
identifier
code
0003 hex
FF hex
83 hex
Description
Byte 8
Byte 9
Byte 10 Byte 11
Register address
Word count
C300 hex
0002 hex
Byte 9
···
Byte 12
Reader/Writer operating
status
4 bytes
Byte 9
Byte 10
Byte 11
Byte 12
Mode
Status information
2 bytes
2 bytes
Byte 8
Exception
code
1 byte

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680s-hmd64-etnV680s-hmd66-etn

Table of Contents