Omron V680S-HMD63-ETN User Manual page 131

V680s series
Hide thumbs Also See for V680S-HMD63-ETN:
Table of Contents

Advertisement

 Enabling Field Extension Mode
1.
Connect all of the Reader/Writers with Ethernet Cables and turn ON the power supplies.
Set a unique IP address for each Reader/Writer in advance.
Refer to Section 5 Preparations for Communications.
2.
Start a Web browser on your computer.
3.
In the address field on the Web browser operation window, enter the IP address of the Master Reader/
Writer (here, 192.168.1.200).
4.
Display the RF Tag Communications Settings View, set the RF Tag communications option to Once or
Auto, and then click the Set Button.
If you specify the FIFO Trigger communications option, multi-Reader/Writer operation will be enabled and a multi-
Reader/Writer execution status error will occur when you restart.
http:// (IP address)
Section 6
Functions
RFID System
129
User's Manual
(Modbus TCP)