IP Address Duplication Error
Turn OFF the power supply to the Reader/Writer, remove the Reader/Writer from the network, correct
the IP addresses, add the Reader/Writer to the network, and turn the power supply back ON.
System Errors
Turn OFF the power supply, check the wiring, and then turn ON the power supply. If the problem does
not change, recovery is not possible for the error. Replace the Reader/Writer.
 Multi-Reader/Writer Execution Error
Check the combination of the Multi-Reader/Writer Mode and the RF Tag communications option.
Or, check the IP address settings to see if the Slave Reader/Writer is using the same IP address as the
Master Reader/Writer.
The RF Tag communications queries that you can use during multi-Reader/Writer operation (Field
Extension Mode or High-speed Traveling Mode) are shown in the following table.
If you use any RF Tag communications query that cannot be used for the Master Reader/Writer, and
Multi-Reader/Write execution error will be indicated in the response.
 Queries That Can Be Addressed to a Master Reader/Writer
RF Tag communications
query
READ DATA
WRITE DATA
DATA FILL
RF TAG OVERWRITE
COUNT CONTROL
READ ID
COPY DATA
LOCK
Multi-Reader/Writer Mode
Field Extension Mode
Supported
Supported
Not supported
Not supported
Supported
Not supported
Not supported
Section 9
Troubleshooting
High-speed Traveling Mode
Supported
Not supported
Not supported
Not supported
Not supported
Not supported
Not supported
RFID System
User's Manual
(Modbus TCP)
235

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680s-hmd64-etnV680s-hmd66-etn

Table of Contents