Omron V680S-HMD63-ETN User Manual page 102

V680s series
Hide thumbs Also See for V680S-HMD63-ETN:
Table of Contents

Advertisement

Section 6
Functions
 Maintenance
 Noise monitor
Communication performance will be reduced when the RF tag or the Reader/Writer are influenced by
ambient noise. The Reader/Writer responds the ambient noise level by using noise monitor function.
The response data includes the following parameters. By checking the noise level, you can check the
influence on the performance of communication with the RF tag in advance. You can also check the
noise level when the trouble occurs.
Noise level (Average)
Noise level (Maximum)
Noise level (Minimumu)
The noise monitor can be performed by means of the following two.
Noise measurement query message from the host.
By sending a Noise measurement query to the Reader/Writer, you can check the noise level.
Refer to MEASURE NOISE in Section 7 Host Communications Specifications for details on the Noise measurement query.
p.182
Noise measurement using Web browser.
You can check the transition graph of the noise level using WEB browser.
By selecting the type of the RF tag, you are also able to visually confirm the stability of communication.
Refer to Noise Monitor View in Section 8 Browser Interface for more information.
p.218
If the noise level that was confirmed by WEB browser screen may affect the performance of
communication, take the following actions.
• If the other Reader/Writers are operating close to the Reader/Writer, ensure the distance between
the Reader/Writers.
p.268, p.269, p.271
• If the equipment close to the Reader/Writer, become a source of noise transceivers, motors,
inverters, and switching power supply is running, ensure the distance until the amount of noise is
sufficiently reduced. Take action, such as enclosing the noise source by metal object.
 GET LOG INFORMATION Query
The GET LOG INFORMATION query obtains the following log information.
Up to 8 records can be recorded in each log. The oldest records are deleted when the logs become
full.
• Query log (query information and operating time for execution)
• Response log (response information and operating time for execution)
• Error log
Host device
Host device
RFID System
100
User's Manual
(Modbus TCP)
This represents the average value of the measured noise level.
00 to 99
This represents the Maximum value of the measured noise level.
00 to 99
This represents the minimum value of the measured noise level.
00 to 99
Reader/Writer
GET LOG INFORMATION
Reader/Writer
Response