Omron V680S-HMD63-ETN User Manual page 37

V680s series
Hide thumbs Also See for V680S-HMD63-ETN:
Table of Contents

Advertisement

V680-A80 Attachment
This Attachment is used to hold V680-D1KP58HTN ID Tags.
Applicable model: V680-D1KP58HTN
20 dia.
12 dia.
3.2 dia.
 High-temperature Applications (V680-D1KP58HTN)
 Data Retention
•Due to the characteristics of EEPROM, any data that is written to an RF Tag may be lost if it is used
in a high-temperature environment that exceeds 125°C for a total of more than 10 hours. Always
reset the data holding time before a total of 10 hours is reached.
•Communications between the Reader/Writer and RF Tags may fail in high-temperature environments
of 85°C or higher. Do not perform communications between the Reader/Writer and RF Tag in a high-
temperature environment of 85°C or higher.
•Due to the characteristics of EEPROM, the UID (RF Tag ID code) may be lost if an RF Tag is used in
a high-temperature environment that exceeds 125°C. Do not use commands that use the UID in
high-temperature environments that exceed 125°C.
•Do not use the ID READ command.
•You cannot use FIFO trigger communications.
 Total Usage Time
This section gives the total time that an RF Tag can be placed at high temperatures.
Total usage time: 4 hours
Total usage time: 1 hour
1 hour at high
temperature*1
1 hour at
2 hours at
25 °C
25 °C
Data retention
The time that the RF Tag is left at temperatures lower than
time reset.
the high temperatures are not included in the total usage time.
Fig. Conceptual Diagram of Resetting the Data Retention Time
*1 High temperatures are those between 125 and 250°C.
11.5
15
50
110
Accessories: 2 nuts (M12)
Total usage time: 9 hours
Total usage time: 6 hours
3 hours at high
2 hours at high
temperature*1
temperature*1
3 hours at
25 °C
M12
Mounting Hole Dimensions
40
1 split pin (nominal dimensions: 3.2-mm dia. × 20-mm length)
3 hours at high
temperature*1
2 hours at
1 hour at
25 °C
25 °C
Data retention
time reset.
Section 1
Product Overview
(Unit: mm)
M12
Data written to the memory
of the RF Tag.
Total usage time: 2 hours
2 hours at high
temperature*1
3 hours at
25 °C
RFID System
User's Manual
(Modbus TCP)
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680s-hmd64-etnV680s-hmd66-etn

Table of Contents