IBM 7378 Problem Determination And Service Manual page 87

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3400 M3 Types 7378 and 7379," on page 141 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Remote access attempt failed. Invalid
userid or password received. Userid
is '%1' from WEB browser at IP
address %2.
(%1 = user ID; %2 = IP address,
xxx.xxx.xxx.xxx)
Remote access attempt failed. Invalid
userid or password received. Userid
is '%1' from TELNET client at IP
address %2.
(%1 = user ID; %2 = IP address,
xxx.xxx.xxx.xxx)
The Chassis Event Log (CEL) on
system %1 cleared by user %2.
(%1 = CIM_ComputerSystem.
ElementName; %2 = user ID)
IMM reset was initiated by user %1.
(%1 = user ID)
ENET[0] DHCP-HSTN=%1, DN=%2,
IP@=%3, SN=%4, GW@=%5,
DNS1@=%6.
(%1 = CIM_DNSProtocolEndpoint.
Hostname; %2 =
CIM_DNSProtocolEndpoint.
DomainName; %3 =
CIM_IPProtocolEndpoint.
IPv4Address; %4 =
CIM_IPProtocolEndpoint.
SubnetMask; %5 = IP address,
xxx.xxx.xxx.xxx; %6 = IP address,
xxx.xxx.xxx.xxx)
ENET[0] IP-Cfg:HstName=%1,
IP@%2, NetMsk=%3, GW@=%4.
(%1 = CIM_DNSProtocolEndpoint.
Hostname; %2 =
CIM_StaticIPSettingData.
IPv4Address; %3 =
CIM_StaticIPSettingData.
SubnetMask; %4 =
CIM_StaticIPSettingData.
DefaultGatewayAddress)
LAN: Ethernet[0] interface is no
longer active.
LAN: Ethernet[0] interface is now
active.
Error
A user has attempted to log
in from a Web browser by
using an invalid login ID or
password.
Error
A user has attempted to log
in from a Telnet session by
using an invalid login ID or
password.
Info
A user has cleared the IMM
event log.
Info
A user has initiated a reset
of the IMM.
Info
The DHCP server has
assigned an IMM IP address
and configuration.
Info
An IMM IP address and
configuration have been
assigned using client data.
Info
The IMM Ethernet interface
has been disabled.
Info
The IMM Ethernet interface
has been enabled.
1. Make sure that the correct
login ID and password are
being used.
2. Have the system
administrator reset the login
ID or password.
1. Make sure that the correct
login ID and password are
being used.
2. Have the system
administrator reset the login
ID or password.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
Chapter 3. Diagnostics