5. Remove the power supply or power supplies from the power-supply cage (see
"Removing a hot-swap power supply" on page 273).
6. Rotate the power-supply cage to its open position (see "Opening the
power-supply cage" on page 154).
7. Remove the air baffle (see "Removing the air baffle" on page 212).
8. Remove the fan cage assembly (see "Removing the fan cage assembly" on
page 243).
9. Disconnect the operator information panel assembly cable from the system
board (see "System board internal connectors" on page 15).
10. Locate the operator information panel assembly release latch just above the
DVD drive.
11. Push up on the release latch while you pull the operator information panel
assembly toward the rear of the server; then, angle the back of the assembly
toward the system board and remove the assembly from the server.
12. If you are instructed to return the operator information panel assembly, follow
all packaging instructions, and use any packaging materials for shipping that
are supplied to you.
Chapter 5. Removing and replacing server components
221