Aa3 - ICP DAS USA Network Device I-7011 User Manual

B&b electronics network device user manual
Table of Contents

Advertisement

2.8 $AA3

Description : Read CJC Temperature
Syntax : $AA3[CHK](cr)
$
delimiter character
AA
address of reading module (00 to FF)
3
command for reading CJC temperature
Response :
Invalid Command :
Syntax error or communication error may get no re-
sponse.
>
delimiter for valid command
?
delimiter for invalid command
AA
address of response module(00 to FF)
(Data)
CJC temperature in degree Celsius.
Example :
Command : $033
Read address 03 CJC temperature, return 25.4°C.
Related Command :
Sec.2.14 $AA9(Data)
Rev:B1.0
Valid Command :
I-7011, I-7018 User Manual
>(Data)[CHK](cr)
?AA[CHK](cr)
Receive : >+0025.4
29