3-4 MOUNTING IN THE BEAM TOWER

- Mounting the detector
1
Select a mounting pattern according to the tower to be used.
Main unit
Mounting pattern
Tamper position
Tamper position
When using the tamper output, install the
detector with the tamper shown above being
Caution
pressed.
Not doing so may cause malfunction of wall
tamper.
2
When installing the detector without the cover, lock the
tamper button with the tamper lock plate on both the
transmitter and receiver.
Tamper lock plate
Tamper button
1
Loosen the screw and
rotate the tamper lock plate.
Caution
• The switch selection is not recognized when locking
the tamper button.
Release the tamper button before selecting a function
using the switch.
• After completing the settings, be sure to lock the
tamper button to check that all LEDs are OFF.
If the tamper button is not locked, the LEDs are kept
ON, which consumes more battery power.
• The monitor jack output is disabled when the tamper
button is locked.
• When locking the tamper button, the beam alignment
test point will be disabled. Complete the alignment
procedure before locking the tamper button.
Main unit
Main unit
+ Chassis
+ Chassis
+ Back box
Tamper position
Tamper position
2
Fasten the screw to lock
the tamper button.
- Mounting the detector separate from the back box
1
Be sure to remove the waterproof packing.
2
Open the wiring guide on the back of the chassis using
pliers as shown.
3
Fix the back box and main unit.
Note>>
• When mounting the back
box and the main unit,
use extension cable with
connector EC-4 (option).
Extension cable
with connector EC-4

3-5 MOUNTING EXAMPLE AT PARTICULAR CASE

1
Avoid installing the transmitter and receiver facing each other
through the corner of the cover.
Transmitter
2
In doing this installation, the maximum detection range shall
be half of the original detection range. (This is to compensate
the attenuation of beam by the corner of the cover.)
ex) SL-200QN 60m/200ft.
-6-
Note>>
• Remove two screws fixing
the waterproof packing.
Up to
150mm
[ Top view ]
Receiver
30m/100ft.