3-6 :,5,1*
This product is provided with wiring based on the assumption that
N.C. wireless transmitters are used.
Connect the cables from the back box (Yellow/Yellow-white,
Green/Green-white, and Black/Black-white) to the respective
terminals on the wireless transmitters.
Receiver
Main unit
5HG
Black
2UDQJH
Brown
Yellow
:KLWH
Green
Blue
Purple
*UD\
Main unit
32:(5
+
12
Back box
+
32:(5
NOTE>>
‡ 7R SHUIRUP WKH ZLULQJ DV VKRZQ DERYH WZR
wireless transmitters are required and one
of them must have two outputs.
Back box
5HG
Power input (+)
Black
Power input (-)
2UDQJH
DQ output
Brown
DQ output
Yellow
Alarm output
:KLWH
Alarm output
Green
/RZ %DWWHU\ RXWSXW
Blue
/RZ %DWWHU\ RXWSXW
Purple
Tamper output
*UD\
Tamper output
7$03(5
DQ
LB
$/$50
&20
&20
NC &20
&20
NC
12
NC
Input
Input
Input
Input
(N.C.)
(N.C.)
(N.C.)
(N.C.)
:LUHOHVV WUDQVPLWWHU
Transmitter
Main unit
Back box
NC
NOTE>>
‡ 7R PRQLWRU DOO VLJQDO RXWSXWV LQGHSHQGHQWO\ LQFOXGH D
wireless transmitters with four inputs or use two wireless
transmitters with two inputs each.
‡ ,I WKHUH LV RQO\ DQ 12 RXWSXW RQ D ZLUHOHVV WUDQVPLWWHU
WKH ORZ EDWWHU\ RXWSXW DQG WDPSHU RXWSXW FDQQRW EH XVHG
6ZLWFK '4 RXWSXW DQG DODUP RXWSXW IURP 1& WR 12
‡ :KHQ \RX ZDQW WR XVH WKH '4 RXWSXW VKDUH WKH WHUPLQDO
ZLWK WKH DODUP ORZ EDWWHU\ RU WDPSHU RXWSXW )RU
information about wiring, see the wiring diagram in "Setting
the D.Q. output" in "4-3" on page 10.
‡ 7KH SRZHU VXSSO\ FDQ EH VKDUHG EHWZHHQ WKH EDFN ER[ DQG
ZLUHOHVV WUDQVPLWWHU E\ XVLQJ EDWWHU\ FRPPRQ XVH XQLW
%DWWHU\ FRPPRQ XVH XQLW %&8 RSWLRQ 
-7-
Main unit
Back box
5HG
5HG
Black
Black
Green
Green
Blue
Blue
Purple
Purple
*UD\
*UD\
32:(5
+
+
32:(5
:DUQLQJ
‡ :KHQ XVLQJ %&8 RSWLRQ  EH VXUH WR
UHDG WKH %&8 PDQXDO 'R QRW LQVHUW
batteries into the wireless transmitter.
'RLQJ VR PD\ UHVXOW LQ ILUH RU H[SORVLRQ
Power input (+)
Power input (-)
/RZ %DWWHU\ RXWSXW
/RZ %DWWHU\ RXWSXW
Tamper output
Tamper output
LB
7$03(5
&20
NC
&20
NC
Input
Input
(N.C.)
(N.C.)
:LUHOHVV WUDQVPLWWHU