Motor 1 over
load
P02.27
protection
coefficient
P02.28
Reserved
P02.29
Reserved
P03 Group
Vector control
Reserved
P03.00
Reserved
P03.01
Reserved
P03.02
Reserved
P03.03
Reserved
P03.04
Detailed instruction of parameters
speed, it is not necessary to adjust the protection
value during low-speed running.
When P02.27=overload protection current of the
motor/rated current of the motor
So, the bigger the overload coefficient is, the shorter
the reporting time of the overload fault is. When the
overload coefficient <110%, there is no overload
protection. When the overload coefficient =116%,
the fault will be reported after 1 hour, when the
overload coefficient=200%, the fault will be reported
after 1 minute.
Setting range: 20.0%~120.0%
63
Function codes
Default
Modify
value
○
100.0%
●
●
○
○
○
○
○