Installation In Conduit; Installation Using A Power Cord - Hach sc100 User Manual

Table of Contents

Advertisement

Installation
Figure 10
Removing Voltage Barrier
J1
J1
S1
S1
J2
J2
U5
U5
J4
J4
NETWORK
NETWORK
INTERFACE
INTERFACE
CARD
CARD
1.
High voltage barrier

3.3.1 Installation in Conduit

3.3.2 Installation Using a Power Cord

Figure 11
Using the Optional Strain Relief and Conduit Plug
1.
Power cord strain relief
16
J3
J3
J5
J5
U9
U9
J6
J6
In hard-wired electrical applications, the power and safety ground service drops for the
instrument must be 18 to 12 AWG. See
opening sealing plug information. See
DANGER
Use of a power cord is not acceptable in Class 1, Division 2 Hazardous Location
Installation (see
Hazardous Location Installation Control Drawing on page
A sealing-type strain relief to maintain the NEMA 4X/IP66 environmental rating and a
power cord less than 3 meters (10 feet) in length with three 18-gauge conductors
(including a safety ground wire) can be used, see
page
43. See
Figure 11 on page 16
assembly. See
section 3.3.3 on page 17
2
2.
Conduit strain relief
PCB
PCB
PCB
PCB
CONNECTOR
CONNECTOR
CONNECTOR
CONNECTOR
NC
NC
COM
COM
NO
NO
NC
NC
COM
COM
NO
NO
RELAY A
RELAY A
RELAY A
RELAY A
RELAY B
RELAY B
RELAY B
RELAY B
DANGER - EXPLOSION HAZARD
DANGER - EXPLOSION HAZARD
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE
UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS.
UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS.
INSULATION MUST
INSULATION MUST
INSULATION MUST
INSULATION MUST
DANGER - RISQUE D'EXPLOSION
DANGER - RISQUE D'EXPLOSION
NE PAS DEBRANCHER TANT QUE LE EST SOUS
NE PAS DEBRANCHER TANT QUE LE EST SOUS
TENSION, A MONIS QU'IL NE S'AGISSE D'UN
TENSION, A MONIS QU'IL NE S'AGISSE D'UN
EMPLACEMENT NON-DANGEROUX
EMPLACEMENT NON-DANGEROUX
2.
Unsnap the barrier latch then pull out to remove the barrier.
Figure 11 on page 16
section 3.3.3 on page 17
Replacement Parts and Accessories on
for strain relief and conduit opening sealing plug
for wiring information.
3
1
1
+
+
+
+
DATA
DATA
DATA
DATA
2
2
– DATA
– DATA
3
3
SERVICE REQUEST
SERVICE REQUEST
4
4
+
+
+
+
V
V
V
V
5
5
GND
GND
6
6
1
1
+
+
+
+
OUT 2
OUT 2
OUT 2
OUT 2
2
2
– OUT 2
– OUT 2
3
3
SHIELD/CHASSIS GND
SHIELD/CHASSIS GND
4
4
+
+
+
+
OUT 1
OUT 1
OUT 1
OUT 1
5
5
– OUT 1
– OUT 1
NC
NC
COM
COM
NO
NO
RELAY C
RELAY C
FIELD WIRING
FIELD WIRING
FIELD WIRING
FIELD WIRING
BE RATED TO
BE RATED TO
BE RATED TO
BE RATED TO
80° C MINIMUM
80° C MINIMUM
80° C MINIMUM
80° C MINIMUM
for strain relief and conduit
for wiring information.
3.
Conduit opening sealing plug
1
2
10).

Hide quick links: