C85 / C95 Non-Metallic And 3 Phase Control Panel Timer - Kasco 8400JF Owner's Instructions Manual

J series decorative aerators
Table of Contents

Advertisement

C85 / C95 non-metallic and 3 Phase
Control Panel Timer
TIME CLOCK SETTING
To set the current time, turn the inner dial clockwise.
Do not set the time by rotating "outer" dial.
Turn the minute hand or small plastic inner dial clock-
wise until the time of day on the outer dial is aligned
with the triangle marker on the inner dial (two o'clock
position).
Example for 10:00 AM. Turn the minute hand clock-
wise until 10:00 AM is aligned with the triangle on
the inner dial. The hour and the minute dial will show
exactly 10:00.
Captive trippers
Triangle marker
(in the on position)
PROGRAMMING
The 24-Hour dial has quarter-hour divisions and AM/
PM indications.
The time switch is programmed by pushing the captive
trippers to the outer ring position for the entire pe-
riod that the aerator is to be turned "ON", i.e., fifteen
7-Day (SW, QRW Models)
minutes for each tripper on the 24-Hour dial. When
the tripper is pushed to the inside, the switch is in the
"OFF" position.
14
PROGRAMMING WITH MANUAL OVERRIDE
SWITCH
Your Timer may have a 3-way manual switch or a
2-way manual switch.
AUTOMATIC MODE
In order to operate the time clock in the automatic
mode, the manual switch must be in the automatic
postion- see diagram.
MANUAL MODE
For the 3-way switch, with the manual override switch
in the lower position, marked "O", the time clock
output will remain Permanently OFF. In the upper
position, marked "I", the time clock output will remain
permanently ON.
For the 2-way switch, with the manual override switch
in the lower position, marked "ON" the time clock
AUTOMATIC MODE
output will remain permanently ON.
MANUAL MODE
SETTING THE TIMER
The timer is a 24 hour time clock with 15 minute increment settings.
The captive trippers change the SPDT relay state when pushed
toward the outside.
1.
Setting time of day
(a) Synchronize the timer by aligning arrow at the 2:00 position
of inner face with the corresponding time of day printed on the
outer ring.
Override Mode
NOTE: Power must be ON to keep time synchronization.
2.
Setting ON time and duration
Locate desired activation time(s) on outer ring (b) and push
trippers to the outside (c). Each tripper represents 15 minutes
activation time. Push as many trippers back as desired for dura-
tion time. When the timer reaches the fi rst tripper, the timer SPDT
3-way manual
contacts will change state and turn ON. It will remain ON for as
long as the following trippers are pushed out. When timer goes
override switch
past last tripper, the timer will return to the OFF mode. The timer
has a selector for (d) AUTOMATIC and ON modes.
Overide Mode
2-way manual
overide switch
7-Day (SW, QRW Models)
I = permanent ON
= automatic
0 = permanent OFF
ON - Permanently ON
AUTO - automatic

Advertisement

Table of Contents
loading

This manual is also suitable for:

3.1jf5.1jf

Table of Contents