1. Inspect the panel for any damage and any components that may have loosened during shipping. Control panel must be
installed a minimum of 5ft (3m in Canada) from the inside wall of the pond, unless separated from the body of water by a
fence wall, or other permanent barrier that will make the unit inaccessible to persons in the water. Install the control panel
to a post structure, side of a building, or other reliable means. This structure must support the panel and prevent
movement/flexing of the panel. Use #10 x 1" or longer screws in the mounting points of the control panel to secure to the
post structure. NOTE: The control panel must be hung upright to be waterproof. It is also advised to mount the panel out of
direct sunlight if possible by mounting the panel in a North direction. Also, mount the panel above the potential flood plain
to prevent water entry during a possible flood event.
2. Set Timer in the control panel to desired ON and OFF times per the Instructions for each specific timer.
Follow all local and national electrical codes for this installation and Consult a qualified electrician or service
3.
person if needed.
a. (For 120V Installations) Plug the aerator cord into the C-25 outlet labeled "UNIT". If lights are included, plug the
Transformer cord into the C-25 outlet labeled "LIGHT". Now you are ready to plug the C-25 into the 120V power
supply on the post and ENJOY YOUR NEW KASCO AERATOR!
b. (For 240V Installations – 3400H, 4400H) All electrical connections to this panel must be made with proper strain
relief cord grip fittings or with conduit connections as required by local and national electric codes. The bottom of
the enclosure is reserved for field installation of these connections.
i. C85 / C95 non-metallic control panel: Incoming power connection: (Power feed) This control panel
requires a 240V or 208V - 4 wire service (L1, L2, N, & G) and must be fed with a power circuit protected
by a circuit breaker or a fused disconnect switch to provide circuit protection and a disconnection
means. C-85 panel requires at least a 30amp protected circuit feeding the panel. C-95 panel requires at
least a 40amp protected circuit feeding the panel. Connect your power feed as detailed in the wiring
diagram provided with this panel. L1 connects to Terminal #1 L2 connects to Terminal #2 N connects to
Terminal N G connects to Terminal GROUND - located on chassis plate Be sure to provide adequately
sized power conductors to prevent excessive voltage drop. Consult with your electrician to properly size
power feed conductors. Use copper conductors only. Aerator power cord connection: Your aerator
(pump) will be provided with a flexible power cord for connection to this control panel. If the power cord
has a plug, you will need to cut it off. The power cord conductors (black, white, green) will need to be
stripped back 1/2". The outer black jacket should be stripped back at least 3inches. Follow the
connection diagram for terminating these three wires to the terminal blocks in the control panel. Black
connects to Terminal #4, White connects to Terminal #5, Green connects to Terminal G.
4. Test the GFCB with the test button now and every 30 days. If lights are installed, they can now be installed per
Instructions included with the lights. Once completed, power can be restored to the panel. Record the following data while
the Aerator is operating in the water under load:
Voltage:
L1-L2 ________
L1-N _________
L2-N _________
Amperage:
L1 __________
L2 __________
Any unauthorized modifications to this control panel will void the UL listing and the Kasco warranty.

Control Panel Installation

1. This control panel requires a hardwire connection for the light kit(s). To connect the light kit(s)
you will need to cut off the power cord plug that is molded to the light kit power cord. Strip back
the black outer jacket of the light kit power cord at least 3 inches to reveal the three internal
wires of the power cord. (black, white, and green conductors). These three wires will need to be
stripped back 1/2". Follow the connection diagram for terminating these three wires to the
terminal blocks in the control panel. Light kit connections: Black connects to Terminal #6, White
connects to Terminal #7, Green connects to Terminal G.
Date installed _____/_____/_____