Robust-Aire
Owner's Manual
800 Deere Rd. Prescott, WI 54021 • 715-262-4488 • sales@kascomarine.com • kascomarine.com
PN: 772155 Rev 6/2020

Advertisement

Table of Contents
loading

Summary of Contents for Kasco Robust-Aire RA1-PM

  • Page 1 Robust-Aire Owner’s Manual 800 Deere Rd. Prescott, WI 54021 • 715-262-4488 • sales@kascomarine.com • kascomarine.com PN: 772155 Rev 6/2020...
  • Page 2: Table Of Contents

    OWNERS MANUAL TABLE OF CONTENTS Safety Precautions……………..……………………….…………………………………………………..…Page 2 Diffuser Installation……………..……………………………………………………………………………….Page 3 Compressor Connections………………………………………………….………………………………..Page 4 No Cabinet (NC) System Installation………….………….…………………………..………….………..Page 6 Base Mount Cabinet Installation………………………………………………...….……….……………..Page 7 Post Mount Cabinet Installation………………………………......………………………..Page 8 Remote Manifold Installation……..………………………………………………………………….……..Page 9 Startup Procedure……………………………………...…………………………………………………...…Page 11 Winter Warning………………………………….………...………………………………...……………...…Page 11 Maintenance……………………………….…………………...……………………………………………...Page 11 Troubleshooting…………………………….…………………...……………………………..……………...Page 12 Warranty………………………………….……………………...…….……………………………..………..Page 13...
  • Page 3: Diffuser Installation

    The effectiveness of the Robust-Aire® Diffuser is dependent on where the diffusers are placed in the pond. Place the Robust-Aire® Diffusers equally from each other at a depth that represents most of the pond. Please contact Kasco with any questions on placement or system operation.
  • Page 4: Compressor Connections

    OWNERS MANUAL Compressor Connections Finish connecting the tubing to the lead hose from the compressor with the supplied barb fitting. Tighten clamps to both supply tubing and compressor hose. Bury tubing from the shore to the compressor. Do not over tighten clamps! Parts included in RA(H)2-NC Systems: No Cabinet Systems: (2) Robust-Aire Diffuser Assembly...
  • Page 5 OWNERS MANUAL (3) ¼” NPT x 3/8” barb brass elbow (4 - 6) Robust-Aire Diffuser Assembly (4) Compressor Vibration Isolation Feet (4 - 6) 3/8” x 100’ SureSink Tubing w/fitting kit (4) ¼” Flat Washer (2) Double Head Compressor (4) ¼” Lock Nut (4) ¼”...
  • Page 6: Base Mount Cabinet Installation

    120V compressors are supplied with a NEMA 5-15 plug. 240V compressors are supplied with flying leads. The leads can be hard-wired into 240V service or an appropriate plug can be installed. Kasco recommends that the site service providing system power have a human-rated Ground Fault Circuit Interrupter outlet (120V) or human-rated Ground Fault breaker (240V) for your protection.
  • Page 7 OWNERS MANUAL Choose a location placed far enough from shore to avoid the potential of flooding. Plantings can be used to help hide the cabinet from sight, however, be sure that both the inlet and outlet vents will not be blocked as air flow is required to keep the compressor from over-heating.
  • Page 8: Post Mount Cabinet Installation

    OWNERS MANUAL Post Mount Cabinet Installation: The post mount cabinet can be attached to a post or to a vertical wall (shed) with electrical service. (2) lag screws are provided to mount the post mount cabinet. Drill (2) 3/16” holes vertically spaced 2 3/8” apart. Install (1) lag screw into the wall or post, leaving the hex head out about ¼”...
  • Page 9: Remote Manifold Installation

    OWNERS MANUAL Remote Manifold Installation Robust-Aire systems that were ordered with the optional remote manifold were pre-built with a single air-line exiting each compressor. Follow the instructions below to assemble and install the remote manifolds. Installation Tools & Materials: ¾” Sch. 40 PVC Pipe (amount to be determined by user) ¾”...
  • Page 10: Startup Procedure

    Sunny days are preferable to cloudy days for system start-up as photosynthesis will supplement oxygen levels as the water is mixed. If you have questions about this procedure, please contact your distributor or e-mail Kasco Customer Service at sales@kascomarine.com...
  • Page 11: Maintenance

    OWNERS MANUAL Winter Operation System owner assumes all risks with operating the Robust-Aire System during winter months. Operating the Robust-Aire system during the winter or freezing temperatures may create open areas of water ® at the diffuser locations. Also, ice will be thin surrounding those areas. Extreme caution should be used to avoid injury or fatality from falling into the water.
  • Page 12: Troubleshooting

    ® ® normal use and service. The Kasco Marine, Inc. obligation under this warranty is limited to replacing or repairing free of charge any defective part within the warranty period. Customer shall pay shipping charges for returning the unit to Kasco or an Authorized Repair Center.
  • Page 13 The best method for establishing warranty period is by the original receipt. Register your system online at: www.kascomarine.com. Once the warranty coverage has been established, the unit may be sent to a Kasco Authorized Repair Center for evaluation and repair. Please contact Kasco Marine prior to shipping to receive any updated information and/or repair form.