Mode connection 2‐2: (Four units in a group) 
Termination reduces signal errors and to avoid signal transmission problems and 
interference. It is always advisable to connect a DMX terminal. 
Put a resistance (120 ohm 1/4W) between pin‐2 (DMX‐) and pin‐3 (DMX+) of the 
last fixture. 
1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120‐ohm 1/4W 
resistor  between  pin  2(DMX‐)  and  pin  3(DMX+)  into  a  3‐pin  XLR‐plug  and  plug  it  in  the 
DMX‐output of the last unit. 
2. Connect the unit together in a "daisy chain" by XLR plug cable from the output of the unit to 
the input of the next unit. The cable cannot be branched or split to a "Y" cable. DMX 512 is a 
very high‐speed signal. Inadequate or damaged cables, soldered joints or corroded connectors 
can easily distort the signal and shut down the system. 
3. The  DMX  output  and  input  connectors  are  pass‐through  to  maintain  the  DMX  circuit,  when 
one of the units' power is disconnected. 
4. Each  lighting  unit  needs  to  have  a  DMX  address  to  receive  the  data  by  the  controller.  The 
address number is between 0‐511 (usually 0 & 1 are equal to 1). 