DMX Input 2 (Control by DMX console)
Channel
1
2 – 109
7. DMX Connections
Please connect the fixtures as below:
Mode connection 1‐1: (One unit in a group)
Mode connection 1‐2: (Two units in a group)
Value
Function
Function Control
000‐025
Blackout
036‐095
DMX Input 1 (Channel 1 ‐ 108) is invalid, DMX Input 2
(Channel 2 ‐ 109) is valid
096‐165
DMX Input 1 (Channel 1 ‐ 108) is valid, DMX Input 2
(Channel 2 ‐ 109) is invalid
166‐235
DMX Input 1 (Channel 1 ‐ 108) is valid, DMX Input 2
(Channel 2 ‐ 109) is valid
236‐255
Blackout
Pixel 01 – Pixel 36 WPY Dimmer (Valid when Input 2
CH1 on 096‐165 or 166‐235)
000‐255
0 ‐ 100%
19A