Set MV / Pump Starts

You can assign a master valve relay or a pump start relay to
each station. This means that any time the station operates, the
relay assigned to it will also turn on. .or example, if a specific
station needs additional water pressure, you may want to
activate a booster pump whenever that station turns on.
NOTE: Stations that have a master valve / pump
relay assigned to them must be wired properly to
activate the relay. See pages 53-55 for instructions.
Turn the dial to “MV or PUMP SELECT.”
The display shows the station number and “MV ON” or
“MV O...” The station number flashes.
Press ñ or ò to select the station number you want to
set.
Press “MAN. START/ADV.”
26
The MV / Pump start setting affects the station in all programs
to which it is assigned.
CAUTION: If an unused station is turned on and
activates a pump start relay, the pump may overheat
or cause a pipe to burst. To prevent operating a pump
with no flow (deadheading), make sure all unused
stations have a zero run time.
ESP-LX+ & LXi+ Installation, Programming, & Operation Guide