Volume Conversion Device EK260

3.11.2 Brief summary of output parameterisation

s Volume pulse output ........................................................... Md.A.. = 1
¢
Selection of the volume counter:
- Vb
Volume at base conditions, undisturbed....... SC.A... = 0002:300_0
- VbD Volume at base conditions, disturbance quantity
0002:301_0
- VbT
Volume at base conditions, total quantity..... SC.A... = 0002:302_0
- Vm
Actual volume, undisturbed ........................... SC.A... = 0004:300_0
- VmD Actual volume, disturbed................................SC.A... = 0004:301_0
- VmT Actual volume, total quantity.......................... SC.A... = 0004:302_0
Setting of the cp value ...................................................... cp.A... = ...
s Status output, logic active or inactive ............................... Md.A.. = 2 or 6
s or event output, logic active or inactive ............................. Md.A
' Selection of status message(s):
- A message in a status St.1 to St.9 ...................................... SpA... = 0.mm_0s:1.1 *
- A message in the system status StSy............................... SpA... = 0.mm_02:2.1 *
- A message in the total status Stat ..................................... SpA... = 0.mm_01:2.1 *
- Message group in a status St.1 to St.9 ............................. SpA... = 1.mm_0s:1.1 *
- Message group in the system status StSy........................ SpA... = 1.mm_02:2.1 *
- Message group in the total status Stat.............................. SpA... = 1.mm_01:2.1 *
s Time-synchronised output, logic active or inactive ......... Md.A.. = 3 or 7
'Setting of the time-point:
- At the start of each month at 0 hrs. ................................... SC.A... = 0001:143_0
- At the start of each month at 6 hrs. ................................... SC.A... = 0002:143_0
- At the start of each day at 0 hrs......................................... SC.A... = 0001:142_0
- At the start of each day at 6 hrs. ........................................ SC.A... = 0002:142_0
- At the beginning of each hour. ........................................... SC.A... = 0001:403_0
- At the beginning of each minute. ....................................... SC.A... = 0001:402_0
- At the beginning of each measurement period.......... .......SC.A... = 0004:156_0
s HF output (only possible for Output 2) ................................Md.O2 = 8
Adjustment ........................................ Aj1O2, Aj2O2, f1.O2, f2.O2 See Chap. 3.11.1.
s Continuous pulse (for test) ................................................. Md.A.. = 99
s Output switched on ............................................................. Md.A.. = 4
s Output switched off ............................................................. Md.A.. = 0
70
* mm = Message (1...16), s = Status number (1...9 for St.1 ... St.9)