Status Register Addresses - Elster EK260 Operating Manual And Installation Instructions

Volume conversion device
Table of Contents

Advertisement

Volume Conversion Device EK260
The customer's lock is normally used by gas customers. It gives access for
changing some values which are not subject to official calibration. The relevant
values are identified in the lists (→ 3) with a "K".
The customer's lock can be opened and closed with "Cod.C " and "St.CL" (→ 3.9) .
Batt. operat
Battery operation
This message is always displayed when the device is being supplied by its internal
battery, i.e. not by an external power supply.
Call Win.1+
Extended call acceptance time window 1
This message is needed for the operation of an FE230 Function Expansion to switch
on the FE230 power supply via an output terminal set as a status output.
The message largely corresponds to message Call Win.1 (see below). If a data
transmission is still running at the end of Call acceptance window 1, the message
Call Win.1+ remains however entered until the data transmission has finished.
Dayl.Sav.Tim The displayed time is daylight saving time
In the system list (→ 3.8) you can set under MdTim whether the EK260 carries out
automatic daylight saving switchover or not.
Call Win.1
Call acceptance time window 1 is active
Call Win.2
Call acceptance time window 2 is active
The EK260 provides two time windows within which a modem connected to the serial
interface accepts calls for data interrogation. Outside of these time windows calls are
ignored, so that, for example, a person located in the station can be called via a
telephone connected to the same telephone line.
The message indicates that the time window 1 (→ 3.12 Interface list) programmed
with CW1.S and CW1.E (Call Win.1) or with CW2.S and CW2.E (Call Win.2) is
active, i.e. the EK260 accepts calls.

3.7.2 Status register addresses

To read out the status information via the interface or to accept it into the user list
(→ page 87), its addresses are needed (cf. table on page 44):
AD *
Description
Stat
Total momentary status
StSy System momentary status
St.1
Momentary status 1
St.2
Momentary status 2
St.3
Momentary status 3
St.4
Momentary status 4
St.5
Momentary status 5
St.6
Momentary status 6
St.7
Momentary status 7
St.8
Momentary status 8
St.9
Momentary status 9
* "AD" = Abbreviated designation (Designation of the value in the display)
50
Address
AD *
1:100
SReg Total status register
2:100
SRSy System status register
1:110
SR.1
2:110
SR.2
3:110
SR.3
4:110
SR.4
5:110
SR.5
6:110
SR.6
7:110
SR.7
8:110
SR.8
9:110
SR.9
Message 15 in StSy
Message 15 in St.1
Message 16 in StSy
Message 16 in St.1
Message 16 in St.2
Description
Status register 1
Status register 2
Status register 3
Status register 4
Status register 5
Status register 6
Status register 7
Status register 8
Status register 9
Address
1:101
2:101
1:111
2:111
3:111
4:111
5:111
6:111
7:111
8:111
9:111