Brief Summary Of Output Parameterisation - Elster EK220 Operating Instructions And Installation Information

Volume conversion device
Table of Contents

Advertisement

3.12.1

Brief summary of output parameterisation

s Volume pulse output ........................................................... Md.A.. = 1 or 5
¢
Selection of the volume counter:
- Vb
Volume at base conditions, undisturbed ...... SC.A... = 0002:300_0
- VbD Volume at base conditions, disturbance quantity SC.A... = 0002:301_0
- VbT
Volume at base conditions, total quantity..... SC.A... = 0002:302_0
- Vm
Actual volume, undisturbed ........................... SC.A... = 0004:300_0
- VmD Actual volume, disturbed................................SC.A... = 0004:301_0
- VmT Actual volume, total quantity.......................... SC.A... = 0004:302_0
Setting of the cp value ...................................................... cp.A... = ...
s Status output, logic active or inactive ............................... Md.A.. = 2 or 6
s or event output, logic active or inactive ............................ Md.A
' Selection of status message(s):
- A message in a status St.1 to St.9 ...................................... SpA... = 0.mm_0s:1.1 *
- A message in the system status StSy............................... SpA... = 0.mm_02:2.1 *
- A message in the total status Stat..................................... SpA... = 0.mm_01:2.1 *
- Message group in a status St.1 to St.9 ............................. SpA... = 1.mm_0s:1.1 *
- Message group in the system status StSy ....................... SpA... = 1.mm_02:2.1 *
- Message group in the total status Stat.............................. SpA... = 1.mm_01:2.1 *
s Time-synchronised output, logic active or inactive ......... Md.A.. = 3 or 7
'Setting of the time-point:
- At the start of each month at 0 hrs. ................................... SC.A... = 0001:143_0
- At the start of each month at 6 hrs. ................................... SC.A... = 0002:143_0
- At the start of each day at 0 hrs......................................... SC.A... = 0001:142_0
- At the start of each day at 6 hrs......................................... SC.A... = 0002:142_0
- At the beginning of each hour. ........................................... SC.A... = 0001:403_0
- At the beginning of each minute. ....................................... SC.A... = 0001:402_0
- At the beginning of each measurement period.................SC.A... = 0004:156_0
s Continuous pulse (for test)................................................. Md.A.. = 99
s Output switched on............................................................. Md.A.. = 4
s Output switched off............................................................. Md.A.. = 0
© Elster GmbH
* mm = Message (1...16), s = Status number (1...9 for St.1 ... St.9)
Volume Conversion Device EK220
= 9 or 10
69

Advertisement

Table of Contents
loading

Table of Contents