6.4 Data register content

6.4.1 Access rights

The "access" column in the tables in the following chapter describes which
lock must be opened in order to change a parameter. All parameter chan-
ges are saved in a log.
Access Meaning
C
Calibration officer
6
CDL
Certification data log
A
Administrator
Cu
Customer
-
No access

6.4.2 "Main" register (main display)

An overview of the most important measurements is presented in the
"Main" register. The contents may vary depending on the parameterization
( chapter 6.4.6.5).
It is not possible to move the cursor to a value in this register
the "ENTER" button, the displayed values are updated.
Display
Meaning
Vb
Volume at base conditions
Vm
Volume at measurement conditi-
ons
P
Pressure
K
Compressibility ratio factor
T
Temperature
C
Conversion factor
6.4.2.1 Vb – Volume at base conditions
The volume measured by the connected gas meter will be converted into a
quantity at base conditions and totaled in this counter.
If there is a fault (see chapter 8 "Faults"), the Vb counter will be stopped
and the volume will be totaled in a special disturbance quantity counter.
6
If a configuration log is in a device.
7
The exception is if the „Main" tab was set to „List" (see chapter 6.4.6.5).
7
. By pressing
Unit
Access Address
3
m
C
3
m
C
bar
-
-
-
°C
-
-
-
Operation
2:300
4:300
7:310_1
8:310
6:310_1
5:310