Electronic Register - Elster V100 Installation Instructions Manual

Volumetric in-line cold water meters
Table of Contents

Advertisement

Electronic register:

The reading is from left to right.
The main display of large digits indicates billable units in cubic metres.
The smaller digits, in the red frame, indicate sub-units.
(1000 Litres = 1 Cubic Metre)
The Tell-tale signals that the meter is in measurement mode and can
be activated by manual rotation of the register without water flowing.
The Tell-tale will continue to display for a short period after activation.
During normal operation, the display will periodically show a self-
checking and alert status mode.
Display: Self-checking mode
8 8 8 8 8 8
8 8 8 8 8
All of the display segments
are temporarily activated
for self-checking.
20724 V100, V110, V200 Inst Instr EN Master AW.indd 4
Main Display
Billable units
0 1 2 3 5 6
02653
Sub units
(red frame)
E
Tell-tale
Display: Alert status mode
0 1 2 3 5 6
- - - - -
Alert code Alert flag
An alert is signalled by an "E" in the alert flag
field. The type of alert can be identified by the
alert code. Refer to the operating instructions.
In the absence of an alert, the five dashes will
be seen in the alert code field, as shown.
28/02/2013 13:02