Flow Switch Adjustment; Trouble Shooting - Kemppi A7 Cooler Operating Manual

Hide thumbs Also See for A7 Cooler:
Table of Contents

Advertisement

4.4 Flow switch adjustment

The flow switch is located inside the cooler, on top of the water tank. If the cooler
is already connected to the power source, you must disconnect it (see chapter 2.5).
Loosen the locking screws of the black slide control and move it to show the desired
flow rate. Tighten the locking screws and reconnect the cooler to the power source.
2,5 1,6
3,0
2,0
1,0
2,5 1,6
3,0
2,0
1,0
2,5 1,6
3,0
2,0
1,0
© Kemppi Oy 2016

4.5 Trouble shooting

See also 3.2. Overheat signal lamp.
Overheat signal lamp is lit.
The unit is overheated.
• Check water circulation.
• Check that there is enough free space in front of and behind the machine for
cooling air circulation.
Error code Err5 or Err 27 on the FastMig panel
• Check the liquid hoses for damages.
• Remove any hose blockages.
• Check water circulation, add liquid if needed.
For further information and assistance, contact your nearest Kemppi service workshop.