Preparing For Operation - Kemppi A7 Cooler Operating Manual

Hide thumbs Also See for A7 Cooler:
Table of Contents

Advertisement

2.5 Preparing for operation

Cooling liquid is harmful! Avoid also contact with skin
or eyes. In case of injury, seek for medical help.
See also 2.4.2. Main parts of cooling unit.
1.
Fasten the filter unit's mounting plate to the
cooler's front panel. Then connect the filter unit
to the snap connector and fasten the unit to the
mounting plate. Inside the cooler there is a flow
switch, factory­adjusted to 1 litres per minute. To
change the flow rate, loosen the locking screws
of the black slide control and move it to show the
desired flow rate.
2.
Connect the mains voltage and control connectors
of the cooler unit to the corresponding connectors
on the base of the power supply. The connection
can be established through the base of the power
supply when the devices are separated or through
the right side of the A7 Cooler unit by removing
the right side plate.
© Kemppi Oy 2016
3.
4.
5.
6.
7.
When A7 Cooler is connected to the power source
for the first time, the cooler function is normally active. To
deselect the cooler function, follow the instructions below
TEST
depending on the power source type in use.
5
A7 Cooler
Attach the power supply on the cooler.
Connect the cooling water hoses with the wire
feed unit, follow colour markings.
Fill the reservoir with cooling liquid. It is preferred
to use Kemppi brand cooling liquid. Also water
can be used, if the temperature doesn't go below
0 degrees Celsius. The capacity of the reservoir is
3 litres.
Switch on the power supply.
Press and hold down the test switch until the
torch hoses are filled with liquid.
1636