Replacing Pneumatic Cylinder On Vertical Dispense Valve Assembly - Conair TrueBlend TB45-4 User Manual

Gravimetric blender
Table of Contents

Advertisement

Maintenance and Repair
Under a strong static charge the sensor can also be screwed 2-3 mm further
into the mixing chamber. This will wipe the material from the probe during
mixing.
NOTE
Do not place the probe too close to the mixing blades. This may destroy it!

9.6.2 Replacing pneumatic cylinder on vertical dispense valve assembly

Removal
Assemble in reverse order.
Note the stroke when installing, otherwise the desired throughput may not be
reached.
NOTE
Fig. 18: Pneumatic cylinder
126
Open the cover [3].
Remove the cylinder cover [4].
Pull the hoses [1] from the cylinder.
Remove the nut [2].
Remove the complete unit.
TrueBlend™
[1] Hoses
[2] Nut
[3] Hopper Lid
[4] Cylinder cover
Edition: February 2007