Alarm Messages and
Troubleshooting
The bottom line, from left to right, shows an
icon when "ON" for the weigh bin valve, the
level sensor logic, the mixer, and the flow
control valve. The level sensor logic is
based on the level sensor and a timer
sequence. The next field with the green
outline shows the current weigh bin weight.
The next button allows the blender to be
started or stopped from this remote screen.
In extrusion mode, when the components
don't add up to 100%, a warning hand will
be displayed above the ON/OFF button to
prevent starting.
In the "Diagnostics Overview" screen shown
at right, note the icon to the left of Reg
material. This indicates the operation of the
regrind valve position. As each subsequent
valve position operates, a similar icon will
appear to the left of that material type.