TrueBlend™
7.7.2.2
Calibrating material throughput
The material throughput calibration is automatically run on startup and is self-
optimizing during production.
The respective dispensing valve(s) are run with reduced batch weight(s) at
startup. The optimum working point is set after several batches. A high mix-
ing precision is quickly reached with a small quantity of material. Finally it
is switched to the preset batch weight.
Conair recommends performing a manual calibration at start-up or material
change with a dramatic change in the bulk density of the material being
blended. This allows the blender to reach its optimal working point more
NOTE
quickly.
Conditions
The weigh bin must be empty.
Press on a material hopper on the
"BLENDER Status" screen.
or
Press on a material hopper on the
"TrueBlend Totals" screen.
The "Setup Component" screen appears.
Press
calibration" screen.
The "Material calibration" screen appears.
Edition: February 2007
to open the "Material
Operation
59