9.5.1 Annual maintenance work

The battery must be replaced during operation.
If it is replaced with the power off, battery-buffered data such as date and
time will need to be reset.
NOTE
Replacing controller battery
Unscrew the four screws [1] on the touch panel case.
Remove the back cover [2].
The 3 Volt lithium cell is positioned on the right side
(viewed from the back).
Pull the tab [3] to remove the battery [3].
Fig. 15: Replacing controller battery
Edition: February 2007
Maintenance and Repair
A replacement
controller battery is
available from Conair.
(Part # 2668900102BA)
Contact Conair Parts
1 800 458 1960
From outside the
United States, call,
814 437 6361
[1] Mounting screws
[2] Cover
[3] Lithium battery with tab