ABB Busch-priOn Series Technical Reference Manual page 42

Knx technical reference manual
Table of Contents

Advertisement

KNX Technical Reference Manual
Busch-priOn
Pos: 22.91 /Produkthandbuch - DIN-A4/Überschriften/2. Ebene/G - L/Lichtszenenaktor @ 9\mod_1269510610443_15.doc @ 53133 @ 2
Light scene actuator
Pos: 22.92 /KNX/Applikationsbeschreibungen/Applikationen - App/Lichtszenenaktor/App. - Lichtszenenaktor - DIN-A4 @ 9\mod_1269509871874_15.doc @ 53118 @
With the "Light scene actuator" application, it is possible to call up scenes that are stored in the device via the receipt of a
scene number on the 1-byte communication object "Scene call-up". A maximum of eight scenes with up to eight actuator
objects can be created.
For triggering different actuators, the size of the actuator groups communication objects can be set under the "Actuator
group type" parameter.
The user has the option of saving the scenes himself. A corresponding save telegram must be received for this (see the
description of the individual parameters).
Light scene actuator objects
No.
Object name
0
Light scene call-up (1 Byte)
1...10
Actuator group A [B...J] (1-bit switching)
1...10
Actuator group A [B...J] (1-bit Venetian blind)
1...10
Actuator group A [B...J] (1 Byte 0..100 %)
1...10
Actuator group A [B...J] (1-byte light scene number)
1...10
Actuator group A [B...J] (Temperature value absolute)
10...19
Enable scene 1 [Scene 2 ... Scene 10]
Pos: 22.93 /Produkthandbuch - DIN-A4/Überschriften/2. Ebene/S - T/Sequenz @ 9\mod_1269511034750_15.doc @ 53143 @ 22
Sequence
Pos: 22.94 /KNX/Applikationsbeschreibungen/Applikationen - App/Sequenz/App. - Sequenz - DIN-A4 @ 9\mod_1269510677004_15.doc @ 53138 @
With the "Sequence " application it is possible to send out multiple telegrams with different values in a predefined sequence
consecutively over the same object.
In contrast to the scene, the "Sequence" application has only one communication object on which up to twelve individual
values are consecutively sent in twelve firmly set times. The times can be freely set from 1 s to 12 h. The "Sequence"
application lends itself to controlling showrooms for example.
The function can be temporarily blocked via an enable object.
Sequence objects
No.
Object name
0
Sequence value (1-bit switching)
0
Sequence value (1 Byte 0..100 %)
0
Sequence value (1 Byte 0..255)
0
Sequence value (1-byte light scene number)
0
Sequence value (2 Byte Float)
0
Sequence value (2 Byte Unsigned)
1
Sequence start
2
Sequence status
4
Enable
Pos: 22.95 /Spezial/Neues Layout 2010/Steuermodule_Neues_Layout_2010/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.doc @ 52149 @
42 | 0073-1-7388 | KNX Technical Reference Manual
®
Data type
1 Byte / DPT18.001
1 Bit EIS1 / DPT 1.001
1 Bit EIS7 / DPT 1.008
1 Byte EIS6 / DPT 5.001
1 Byte / DPT 18.001
2 Byte EIS5 / DPT 9.001
1 Bit EIS1 / DPT 1.001
Data type
1 Bit EIS1 / DPT 1.001
1 Byte EIS6 / DPT 5.001
1 Byte EIS14 / DPT 5.010
1 Byte / DPT 18.001
2 Byte EIS5 / DPT 9.xxx
2 Byte EIS10 / DPT 7.001
1 Bit EIS1 / DPT 1.001
1 Bit EIS1 / DPT 1.001
1 Bit EIS1 / DPT 1.001
Flags
C, W, U
C, W, T, U
C, W, T, U
C, W, T, U
C, W, T, U
C, W, T, U
C, W, T
Flags
C, W, T, U
C, W, T, U
C, W, T, U
C, W, T, U
C, W, T, U
C, W, T, U
C, W
C, T
C, W