Alarm Clock - ABB Busch-priOn Series Technical Reference Manual

Knx technical reference manual
Table of Contents

Advertisement

Pos: 22.55 /Produkthandbuch - DIN-A4/Überschriften/2. Ebene/U - Z/Wecker @ 9\mod_1269505094679_15.doc @ 52904 @ 2

Alarm clock

Pos: 22.56 /KNX/Applikationsbeschreibungen/Display - GUI/Wecker/App. - Wecker - DIN-A4 @ 9\mod_1269504649733_15.doc @ 52899 @ 22
Alarm times (alarm clock times) can be defined with the "Alarm-clock" application. The times are set by the user with the
push-button/rotary control element. When the set time is reached, a signal tone is triggered on the device which can be
confirmed via the push-button/rotary control element.
When the alarm time has been reached, additional functions can be integrated into the alarm call function via a
communication object. In addition, there is the option of sending out an advanced telegram, i.e. a telegram which is triggered
before reaching the alarm time. For the activation of different actuators, the size of the "Switching" and "Advanced switching"
communication objects is adjustable under the "Object type" parameter.
Alarm clock objects
No.
Object name
0
Acknowledgement
1
Snooze
2
Switching (1-bit switching)
2
Switching (1-bit moving)
2
Switching(1 Byte 0..100 %)
2
Switching (scene call-up)
2
Switching(1 Byte 0..255)
2
Switching(2 Byte Unsigned)
2
Switching (relative temperature)
2
Switching (absolute temperature)
3
Switching, advanced (1-bit switching)
3
Switching, advanced (1-bit moving)
3
Switching, advanced(1 Byte 0..100 %)
3
Switching, advanced (scene call-up)
3
Switching, advanced(1 Byte 0..255)
3
Switching, advanced(2 Byte Unsigned)
3
Switching, advanced (relative temperature)
3
Switching, advanced (absolute temperature)
Pos: 22.57 /Spezial/Neues Layout 2010/Steuermodule_Neues_Layout_2010/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.doc @ 52149 @
Data type
1 Bit EIS1 / DPT 1.001
1 Bit EIS1 / DPT 1.001
1 Bit EIS1 / DPT 1.001
1 Bit EIS7 / DPT 1.008
1 Byte EIS6 / DPT 5.001
1 Byte / DPT 18.001
1 Byte EIS14 / DPT 1.010
2 Byte EIS10 / DPT 7.001
2 Byte EIS5 / DPT 9.001
2 Byte EIS5 / DPT 9.001
1 Bit EIS1 / DPT 1.001
1 Bit EIS7 / DPT 1.008
1 Byte EIS6 / DPT 5.001
1 Byte / DPT 18.001
1 Byte EIS14 / DPT 5.010
2 Byte EIS10 / DPT 7.001
2 Byte EIS5 / DPT 9.001
2 Byte EIS5 / DPT 9.001
KNX Technical Reference Manual | 0073-1-7388 | 33
Flags
C, W, U
C, W, U
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T

Hide quick links: