◆Controller Over-Current Cut Settings

CUR represents controller over-current cut settings. CUR value can
be changed from 7.0A to 22.0A. The default value is 15A.
To change basic settings, press the UP/DOWN button to increase
or decrease the value of the current.
Hold the MODE button for 2s and then return to previous menu.

◆Power Assistant Sensor Settings

The Direction of Power Assistant Sensor Settings
PAS represents power assistant sensor settings. "run-F" means
forward direction, while "run-b" means back direction. The default value is
"run-F".
To change The Direction of Power Assistant Sensor Settings, press
the UP/DOWN button to select F or b.
Briefly press the MODE button and then access settings mode of
PAS sensitivity.

The Sensitivity of PAS Settings

SCN represents the sensitivity of PAS settings. The sensitivity value
ranges from "2" to "9". "2" is the strongest, "9" is the weakest. The default
value is "2".
CUR Settings Interface
Direction of PAS Sensor Settings
11