Cabinet
Cleaning the interior of the cabinet
WARNING! Obey the safety instructions given in Safety instructions for
ACS880 multidrive cabinets and modules (3AUA0000102301 [English]).
If you ignore them, injury or death, or damage to the equipment can
occur.
WARNING! Use a vacuum cleaner with an antistatic hose and nozzle, and wear a
grounding wristband. Otherwise an electrostatic charge can build up and damage
the circuit boards.
1. Stop the drive and do the steps in section
before you start the work.
2. Open the cabinet doors.
3. Clean the interior of the cabinet. Use a vacuum cleaner and a soft brush.
4. Clean the air inlets of the fans and air outlets of the modules (top).
5. Clean the air inlet gratings on the doors (see below).
6. Close the doors.
Cleaning the door air inlets (IP22 and IP42)
Refer to the drawing below.
1. Remove the fasteners at the top of the grating.
2. Lift the grating and pull it away from the door.
3. Vacuum clean or wash the grating on both sides.
4. Reinstall the grating in reverse order.
1
Electrical safety precautions
2
Maintenance 107
3
(page 64)
5