3.2 LUBRICATION GUIDE

For best value and longest uninterrupted service,
the ES---8 compressor part of the Integral Compres-
sor/Dryer package is factory filled and tested with a
long life lubricant.
WARNING
!
Mixing of other fluids within the compressor will
void all warranties.
If, due to unavailability or other reasons, other fluids
are required, follow Lubrication Guide below.
WARNING
!
"The Plastic Pipe Institute recommends against the
use of thermoplastic pipe to transport compressed
air or other compressed gases in exposed above
ground locations, e.g. in exposed plant piping." (I)
Sullube 32 should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints. Cer-
tain other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.

3.3 LUBRICATION CHANGE RECOMMENDATIONS

AMBIENT
TEMPERATURE
---10_F to +90_F
(---23_C to +32_C)
(I) 8000 hours or once a year.
LUBRICATION
SRF 1/4000 (Std. Fill)
Sullube 32
Sullair LLL---4---32
Food Grade CP---4600---32---F
SPECIFICATIONS
For light ---duty high---humidity service where con-
densed moisture and emulsification (mayonnaise)
may occur, the fluid change interval must be re-
duced to 300 hours maximum. A non---detergent
fluid with rust, oxidation and foam inhibitors and
good water separation characteristics should be
used.
WARNING
!
Mixing of other fluids within the compressor will
void all warranties.
Contamination of non---detergent mineral fluids with
traces of ATF or detergent motor fluids may lead to
operational problems such as foaming, filter plug-
ging, orifice or line plugging.
NOTE
Flush system when switching lubricant brands.
When ambient conditions exceed those noted or if
conditions warrant use of "extended" life lubricants,
contact Sullair for recommendation.
Sullair encourages the user to participate in a fluid
analysis program. This could result in a fluid change
interval that is different from those stated in this
manual.
FLUID CHANGE
PERIOD (HRS.)
4000
8000 (I)
8000 (I)
8000 (I)
Section 3
FILTER CHANGE
PERIOD (HRS.)
4000
8000 (I)
8000 (I)
8000 (I)