3.3

LUBRICATION GUIDE

Refer to Figure 3-1 for the fluid fill port location.
tested at the factory with (35 GAL) Sullube lubricant.
CAUTION
Contamination of compressor fluids with
mineral oil or other fluids can cause foam-
ing, filter plugging, or orifice line obstruc-
tion.
CAUTION
Do not mix different types of lubricants.
Mixing lubricants can cause malfunctions
or compressor damage: will void the com-
3.4

APPLICATION GUIDE

Sullair encourages its customers to participate in a
fluid analysis program with the fluid suppliers. In
some cases the analysis results suggest a fluid
change interval which differs from the User Manual.
Contact a Sullair representative for details.
3.5
LUBRICATION CHANGE RECOMMENDATIONS AND
MAINTENANCE, FLUID FILTER AND SEPARATOR
LUBRICANT
Sullube
A - 8,000 hours or once per year.
C - When measured pressure loss exceeds 20 psig (1.3 bar).
D - When measured pressure loss exceeeds 10 psig (0.7 bar).
E - When required as the result of fluid analysis or known contamination.
G - Every 2,000 hours.
26
1. Fluid Fill Port
2. Fluid Level Sight Glass 5. Relief Valve
3. Fluid Drain Valve
FLUID CHANGE
FLUID FILTER CHANGE
A,E
Figure 3-1: Fluid Fill Location
NOTE
When performing a fluid change or topping
off the fill, the proper level should be at half
of the sight glass, with the machine off.
Mixing, changing or adding other lubricants
within the compressor unit may void the
air-end warranty.
SEPARATOR CHANGE
G,C
SECTION 3
4. Air/Oil Separator Tank
A,D