Sullair ES-8 Operator's Manual And Parts List page 18

Integral air compressor/dryer & filter
Table of Contents

Advertisement

Section 3
SPECIFICATIONS
Figure 3 ---2 Integral Refrigerant ---Type Dryer Specifications
Flow Capacity
(I)
Air Inlet/Outlet Connection (MPT)
Refrigerant Compressor HP/KW Rating
Maximum Heat of Rejection (BTU/HR /KCAL/HR)
Cooling Air Flow (CFM/M
Refrigerant/Charge (lbs/kg)
Standard Voltage (Optional)
Total Power Input --- Amps/Coulombs
Height (in./mm)
Width (in./mm)
Length (in./mm)
Weight (ES--- 8 30HP/22KW) lbs/kgs
(I) Flow Capacity rating is based on 118 psig (8.1 bar) air outlet pressure and 85
ambient temperature.
(II) Voltage Code:
FLUID FILTER
Type:
Micron:
Internal Bypass Valve Set at 25 psig (1.7 bar)
FLUID SEPARATOR ELEMENT
Type:
Efficiency at Maximum Capacity:
12
MODEL
CFM at 39
_
F (4
_
C) Evaporator
M
/min. at 4
C Outlet Air Temperature
#
_
Power Input (HP/KW)
Drain Connection (FPT)
3
/MIN)
(II)
A --- 115/1/60
B --- 230/1/60
_
F (30
_
C)
Spin on, Sullair Proprietary
23 Microns Abs.
Push In Cartridge, Sullair Proprietary
5PPM Maximum
ES--- 8
114 (60 Hz)
95 (50 Hz)
3.23 (60 Hz)
2.69 (50 Hz)
1.1 / .82
1"
1/4
1/2 / .5
8308 / 2094
331 / 9.4
.81 / .37
A/B
9.0 / 32400
42/1067
36/914
60/1524
1658/752

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF