The air/fluid mixture discharges directly into the
fluid management system.
The fluid cooler bypass valve helps assure proper
cooling by directing the fluid to the fluid cooler
when discharge temperature reaches the thermo-
stat temperature setting.
During start ---up in cool ambient conditions, the
cooler pressure drop may cause the filter bypass
valve to open up, assuring adequate fluid supply to
the compressor.
All fluid entering the compressor unit passes
through the replaceable fluid filter element. This re-
placeable filter element contains a built ---in bypass
valve. Under conditions of restricted flow through
the element, the bypass valve helps ensure ade-
quate compressor fluid flow, as well as helps pre-
vent element failure.
FLUID MANAGEMENT SYSTEM
The fluid management system consists of a multi--
chambered primary/secondary separator, the fi-
nal air/fluid separator element, cooler bypass
and fluid filter.
As compressed air/fluid enters the sump, the first
18
fluid separation takes place due to a reduction of
flow speed coupled with a change of direction of
the flow within the sump housing. Then the com-
pressed air reaches the separator where the finest
fluid drops and mist are separated.
The minimum pressure/discharge check valve is
mounted on the compressor drive housing. Its
functions are as follows:
1. Maintains a minimum sump pressure of 60 psig
(4.2 bar) under full load operation to help assure
adequate fluid pressure.
2. Acts as a check valve to isolate the compressor
from the system at shutdown or unload.
DRIVE MOTOR
The drive motor consists of a squirrel cage induc-
tion motor which is connected to the integrated
drive gearing by a drive coupling.
5.4 COMPRESSOR COOLING SYSTEM, FUNC-
TIONAL DESCRIPTION
The compressor cooling system consists of a fluid
cooler, fan and cooler shroud.
The fan is mounted on the compressor shaft. Air is
drawn through the motor adaptor by the fan and
exits through the coolers on top of the compressor.
The air provides cooling for compressor fluid and