Accessories
9.26 Assembly kit for reversing contactor assemblies (sizes S00 to S3)
9.26.2

Mounting size S00

The reversing contactor assemblies can be built from contactors with screw connections or
spring-loaded connections:
● Standard contactor (Q 11) for direction of rotation 1 (clockwise rotation): Left
● Standard contactor (Q 12) for direction of rotation 2 (counterclockwise rotation): Right
The illustration below shows example procedures for assembling the reversing contactor
assembly 3RA23 size S00 with screw-type connection. Instructions 1 to 5 show how to
assemble the contactors using the mechanical interlock and the connecting clips.
Assembling the reversing contactor assembly with screw-type connection - size S00
368
Insert the mechanical interlock into the opening on the right-hand side of contactor Q11.
Insert the connecting clips into the openings on contactor Q12.
Connect contactors Q11 and Q12 together.