Cisco D9865 Installation And Operation Manual page 206

Hide thumbs Also See for D9865:
Table of Contents

Advertisement

Alarm
Message
Type
System Startup
Set
Clear
LMI setup
Set
Clear
Param Storage
Set
Clear
7-8
Message
System Startup
Backup/Restore
System Startup
LMI SDRAM exhaust
test failed
LMI Video SDRAM
exhaust test passed
DB NVS flushing
ignored
RAM flush to NVS
failed
DB Factory Reset
failed
DB flushing
completed
DB Factory Reset
completed
D9865 Satellite Receiver Installation and Operation Guide
Cause/Remedy
Cause: Restarted the
D9865 Satellite
Receiver.
Remedy: None. It
will automatically
reset after 1 second.
Cause: Backup/
Restore updated
settings during a
system startup.
Remedy: None. It
will automatically
reset after 1 second.
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the unit,
and notify customer
service if the problem
persists.
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the unit,
and notify customer
service if the problem
persists.
Description
Severity
Indicates the
Minor
D9865 has
restarted.
DDR RAM on
Major
LMI bus not
working.
DDR RAM on
LMI bus OK.
Non-volatile
Major
storage system
failed to update
fully.
Non-volatile
storage system
failed during
factory reset.
Successful NVS
update.
Successful
action.
4035197 Rev C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents