YASKAWA SI-EN3/V Installation Manual page 21

Ac drive-v1000 option ethernet/ip
Hide thumbs Also See for SI-EN3/V:
Table of Contents

Advertisement

Figure 9
V1000
Figure 9 Remove the Terminal Cover on an IP20/NEMA Type 1 Drive
(Models CIMR-VBA0006F to BA0018F; 2A0008F to 2A0069F;
7.
For models CIMR-VBA0001F to BA0003F, 2A0001F to 2A0006F, loosen the
screws attaching the NEMA Type 1 conduit bracket to the drive to remove the
NEMA Type 1 conduit bracket.
Figure 10
V1000
8.
On NEMA Type 1 enclosure models (CIMR-VBA0001F to BA0003F, 2A0001F to
2A0006F), the screw for the drive ground terminal also acts as one of the screws
that attaches the NEMA Type 1 conduit bracket to the drive. Reattach the NEMA
Type 1 conduit bracket according to
ground wire to the drive ground terminal.
Note: The four different ground wires packaged with the option connect the option to different drive
models. Select the proper ground wire depending on drive size. Refer to
ground wire selection by drive model.
YASKAWA ELECTRIC TOBP C730600 60A V1000 Option EtherNet/IP Installation Manual
4A0001F to 4A0038F)
Figure 10 Remove the NEMA Type 1 Conduit Bracket
5 Installation Procedure
Figure 11
and connect the drive-side of the
Table 7
on page
20
for