Table 3 Male 8-way Ethernet Modular Connector (Customer Supplied)
Male EtherNet 8-Way Modular Connector
<1> Not used for 10 Mbps and 100 Mbps networks.
u
Option LED Display
The option has four LEDs:
Bi-color Status LEDs:
• Module status (MS) red/green
• Network status (NS) red/green
Green Ethernet LEDs:
• Network speed-10/100 (MS) green
• Link status and network activity-Link/Act (NS) red/green
The operational states of the option LEDs after the power-up diagnostic LED sequence is
completed are described in
process to complete before verifying the states of the LEDs.
Indication
Name
Color
Green
Green
MS
Red
Red
Green/Red
YASKAWA ELECTRIC TOBP C730600 60A V1000 Option EtherNet/IP Installation Manual
Table
4. Wait at least 2 seconds for the power-up diagnostic
Table 4 Option LED States
Operating Status
Status
OFF
Power supply OFF
ON
Option operating
Flashing
Option initializing
ON
Fatal error occurred
Flashing
Non-fatal error occurred
Flashing
Option self-test
4 Option Components
Pin
1 (Pair 2)
Transmit data (TXD) +
2 (Pair 2)
Transmit data (TXD) -
3 (Pair 3)
Receive data (RXD) +
4 (Pair 1)
Not used
5 (Pair 1)
Not used
6 (Pair 3)
Receive data (RXD) -
7 (Pair 4)
Not used
8 (Pair 4)
Not used
Power is not being supplied to the
drive
The option is operating normally
The option is configuring an IP
address
The option has detected a fatal
(unrecoverable) error
The option has detected a non-fatal
(recoverable) error
The option is in self-test mode
Description
<1>
<1>
<1>
<1>
Remarks