3 SPECIFICATIONS

3.6 Encoders that can be Connected

3 - 14
The encoders that can be connected to the QD62(E/D) are described below.
(1) Encoders that can be connected to the QD62 and QD62E
• Open collector output type encoders
• CMOS level voltage output type encoders
(Verify that the encoder output voltage meets the specifications for the QD62
and QD62E.)
(2) Encoders that can be connected to the QD62D
• Line driver output type encoders
(Verify that the encoder output voltage meets the specifications for the
QD62D.)
POINT
The following encoders cannot be used with the QD62(E/D).
• TTL level voltage output type encoders