Mitsubishi QD60P8-G User Manual page 31

Melsec-q series, channel isolated pulse input module
Table of Contents

Advertisement

3 SPECIFICATIONS
Device
No.
Operating condition
Y1
setting request flag
Y8
CH1
Y9
CH2
YA
CH3
YB
CH4
Error reset
request
YC
CH5
YD
CH6
YE
CH7
YF
CH8
Y10
CH1
Y11
CH2
Y12
CH3
Comparison
Y13
CH4
signal reset
Y14
CH5
request
Y15
CH6
Y16
CH7
Y17
CH8
Y18
CH1
Y19
CH2
Y1A
CH3
Y1B
CH4
Count
enable
Y1C
CH5
Y1D
CH6
Y1E
CH7
Y1F
CH8
3 - 7
(2) Details of output signals (programmable controller CPU
QD60P8-G)
The following table indicates the ON/OFF timings and functions of the output
signals.
Signal name
OFF: No operating
condition
setting
request
ON : Operating
condition
setting
request
OFF: No error reset
request
ON : Error reset
request
OFF: No
comparison
signal reset
request
ON : Comparison
signal reset
request
OFF: Count
operation
stop
ON : Count
operation
start
*1: Initial value set at power-on or when the programmable controller CPU is reset.
• This signal turns ON to make the "comparison output
setting value" and other setting data of the buffer
memory valid.
• When this signal turns ON, the setting data are reflected
on the module.
• When this signal turns ON, the "sampling pulse
number", "accumulating count value" or "input pulse
value" assigned to the buffer memory for each channel
is reset.
• When this signal is turned ON in the sequence program,
it should be kept ON for longer than 10ms.
• For details on the ON/OFF timing of this signal, refer to
the item of the input signal (X1).
• If the error occurrence signal (X8 to XF) has turned ON
due to the error occurrence, turning ON this signal
clears that error.
• For details on the ON/OFF timing of this signal, refer to
the item of the input signal (X8 to XF).
• If the accumulating counter comparison flag (X10 to
X17) has turned ON, turning ON this signal clears the
accumulating counter comparison flag.
• For details on the ON/OFF timing of this signal, refer to
the item of the input signal (X10 to X17).
• This signal turns ON when count operation is started.
• When this signal turns ON, the count operation of the
"sampling pulse number", "accumulating count value" or
"input pulse value" assigned to the buffer memory for
each channel is started.
• For details on the ON/OFF timing of this signal, refer to
the item of the input signal (X1).
MELSEC-Q
Details
Initial
value
*1
OFF
OFF
OFF
OFF
3 - 7