Installing the rack server

Installing the rack server
Do not expose the server to extreme environmental conditions (see chapter
!
data"). Protect it from dust, humidity and heat.
Installation steps
Mount assembly kit and insert server (see order lists for location diagram prepared with Rack
Architect)
Connect the devices to the server in accordance with the rack configuration.
Connecting the server to the line voltage
Routing cables

Fit assembly kit and rack-mount the server

Ê
Using the mounting aid (stencil) mark the position of the attachment points on the support
upright of the server. Refer to the information on the mounting aid. The server requires five
height units.
One height unit corresponds to 4.445 cm and is defined by the hole sequence on the
i
support upright round hole-oblong hole-round hole . The oblong hole marks the middle of a
height unit.
1
Ê
Place the spring nuts in the groove of the support uprights at the marked attachment points (1 -
4).
Ê
If necessary, adjust the position of the nuts in the groove until they lock into the correct position
(5).
A26361-K632-Z100-1-7619
ca 45˚
2
3
4
Installation
"Technical
5
5
17