9.11 Panel PCB ASSY / Rubber key / Top cover sensor / Top cover actuator

(1) Pull out the top cover sensor harness from the panel PCB ASSY, and release it from the
securing fixtures.
(2) Remove the taptite bind B M3x10 screw, and remove the top cover sensor holder from the
panel ASSY.
(3) Release the two hooks, and remove the top cover sensor from the top cover sensor holder.
(4) Lift the top cover actuator and remove it from the boss on the panel ASSY along with the
top cover actuator spring. Remove the top cover actuator spring from the top cover
actuator.
(5) Release the four hooks. Lift the hook side of the panel PCB ASSY, and slide it in the
direction of the arrow to remove the panel PCB ASSY from the panel ASSY.
(6) Remove the rubber key from the panel ASSY.
(7) Remove the two LED guides from the panel ASSY.
Top cover sensor harness
Top cover actuator
Top cover actuator
spring
Boss
HARNESS ROUTING: Refer to
Assembling Note:
• Attach the top cover actuator spring on the position described in the illustration above.
Top cover
actuator spring
LED guides
Hooks
Boss
Top cover actuator
Panel ASSY
"2. Panel PCB
Panel PCB ASSY
Top cover sensor
Hooks
Fig. 3-20
ASSY".
3-23
Rubber key
Hooks
Panel ASSY
Taptite bind B M3x10
Top cover sensor holder
Confidential