Sm 335 Parameters For Comparator Mode - Siemens SIMATIC SM 335 Manual

High-speed analog input/output module for the simatic s7-300
Hide thumbs Also See for SIMATIC SM 335:
Table of Contents

Advertisement

Special SM 335 Operating Modes
5.2.2

SM 335 parameters for Comparator mode

Restrictions
The parameters for
WR_PARA.
Data Record 1
The dynamic parameters are entered in data record 1 on the SM 335 (see
Table 5-2).
Table 5-2
Byte
0
1
2
3
4
5
6
7
8
9
10
11
12
13
5-10
"Comparator" mode
Data record 1 on the SM 335 for "Comparator" mode
Analog output value 1, high-order byte
Analog output value 1, low-order byte
Analog output value 2, high-order byte
Analog output value 2, low-order byte
Analog output value 3, high-order byte
Analog output value 3, low-order byte
Comparison value for "Comparator 1", high-order byte
Comparison value for "Comparator 1", low-order byte
Comparison value for "Comparator 2", high-order byte
Comparison value for "Comparator 2", low-order byte
Comparator time
Dynamic measuring cycle control
Comparator control byte
Reserved
SM 335 – High-Speed Analog Input/Output Module for the SIMATIC S7-300
can be passed with system function 55
Content
6ES7 335-7HG00-8BA1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents