Command and Response Table for DSP SIS Commands

Command
Attenuation
Set attenuation
View attenuation
Mute
Set mute
View mute status
NOTES:
X1)
= Object ID (OID) number
X1!
= Attenuation value
X1@
= Mute status

Object ID (OID) Number and Value Range Tables

NOTES:
Output
Output 1
Output 2
ASCII Command
(host to  unit)
E
X1)
X1!
}
G
*
AU
E
X1)
}
G
AU
E
X1)
X1@
}
M
*
AU
E
X1)
}
M
AU
Attenuation values should be entered as negative integers.
Attenuation values must be in 1 dB steps.
OID
60000
60001
Response
(unit to host)
X1)
X1!]
DsG
*
X1!]
X1)
X1!]
DsG
*
X1)
X1@]
DsM
*
X1@]
X1)
X1@]
DsM
*
See
Object ID (OID) Number and Value Range
Tables
below for Input and Output OID numbers.
See
Object ID (OID) Number and Value Range
Tables
below for Input and Output OID numbers.
= muted,
= ummuted
1
0
Attenuation Value
Range
to -
0
100
to -
0
100
AXI 02 AT • Remote Control
Additional Description
(verbose 2 and 3 response)
(verbose 2 and 3 response)
32