Siemens SIRIUS 3RW44 System Manual page 237

Soft starters
Hide thumbs Also See for SIRIUS 3RW44:
Table of Contents

Advertisement

Inline circuit fused version with 3NE1 SITOR all-range fuse (semiconductor and line protection)
F´1
Q21
Q11
Soft starters
All-range fuses
Rated
current
Q11
F'1
Type
A
Type
3)
Type of coordination 2
: I
= 65 kA
q
3RW44 22
29
3NE1 020-2
36
3NE1 020-2
3RW44 23
3RW44 24
47
3NE1 021-2
57
3NE1 022-2
3RW44 25
3RW44 26
77
3NE1 022-2
3RW44 27
93
3NE1 024-2
3RW44 34
113
3NE1 225-2
3RW44 35
134
3NE1 227-2
3RW44 36
162
3NE1 227-2
3RW44 43
203
3NE1 230-2
3RW44 44
250
3NE1 331-2
3RW44 45
313
3NE1 333-2
3RW44 46
356
3NE1 334-2
3RW44 47
432
3NE1 435-2
3RW44 53
551
2 x 3NE1 334-2
3RW44 54
615
2 x 3NE1 334-2
3RW44 55
693
2 x 3NE1 334-2
3RW44 56
780
2 x 3NE1 435-2
3RW44 57
880
2 x 3NE1 435-2
3RW44 58
970
2 x 3NE1 435-2
3RW44 65
1076
3 x 3NE1 334-2
3RW44 66
1214
3 x 3NE1 335-2
1) If the ramp-down function "Combined braking" is selected, no braking contactor is required.
If the ramp-down function "DC braking" is selected, a braking contactor must also be used (see table for type).
For applications with large centrifugal masses (J
2) Additional auxiliary relay K4: LZX:RT4A4T30 (3RW44 soft starter with rated control supply voltage 230 V AC), LZX:RT4A4S15 (3RW44 soft starter with
rated control supply voltage 115 V AC).
3) The types of coordination are explained in more detail in the Technical information LV 1 T under – Fuseless Load Feeders.
SIRIUS 3RW44 System Manual
GWA 4NEB 535 2195-02 DS 04
M
3~
Rated current
A
80
80
100
125
125
160
200
250
250
315
350
450
500
560
500
500
500
560
560
560
500
560
> J
Load
Motor
Line contactors
up to 400 V
Voltage
Size
(optional)
Q21
V
Type
690 +5 %
00
3RT10 34
690 +5 %
00
3RT10 35
690 +5 %
00
3RT10 36
690 +5 %
00
3RT10 44
690 +5 %
00
3RT10 45
690 +5 %
1
3RT10 46
690 +5 %
1
3RT10 54
690 +5 %
1
3RT10 55
690 +5 %
1
3RT10 56
600 +10 %
1
3RT10 64
460 +10 %
2
3RT10 65
690 +5 %
2
3RT10 75
690 +5 %
2
3RT10 75
690 +5 %
3
3RT10 76
690 +10 %
2
3TF68 44-0CM7
690 +10 %
2
3TF68 44-0CM7
690 +10 %
2
3TF69 44-0CM7
690 +10 %
3
3TF69 44-0CM7
690 +10 %
3
2 x 3TF69 44-0CM7
690 +10 %
3
690 +10 %
2
690 +10 %
3
) we recommend the function "DC braking.
General Technical Data
1)2)
Braking contactors
(for typical circuit see page 9-5)
Q91
Q92
Type
Type
3RT15 26
3RT15 26
3RT15 35
3RT15 35
3RT10 24
3RT10 35
3RT10 25
3RT10 36
3RT10 34
3RT10 44
3RT10 36
3RT10 45
3RT10 44
3RT10 45
3RT10 44
3RT10 54
3RT10 44
3RT10 55
3RT10 54
3RT10 56
3RT10 54
3RT10 56
3RT10 55
3RT10 64
3RT10 64
3RT10 66
3RT10 64
3RT10 75
3RT10 65
3RT10 75
3RT10 65
3RT10 75
3RT10 75
3RT10 76
3RT10 75
3RT10 76
3RT10 75
3TF68
3RT10 76
3TF68
10-19

Advertisement

Table of Contents
loading

Table of Contents